.e measurement of input and output torque of a precision reducer, the core component of an industrial robot, plays a vital role in evaluating the robot’s performance. .e TMSIS and TMSOS of a vertical cylindrical high-precision reducer detector were designed and investigated in this study to realize the accurate measurement of input and output torque of the reducer. Because a transmission chain connects the torque transducer and the reducer, the characteristics of the inevitable additional torque are analyzed in detail. A torque calibration device is developed to realize the calibration of the torque measurement system. .e readings of the torque calibration device are compared with the data of the instrument’s torque measurement system to realize the instrument’s torque calibration..e improved particle swarm optimization and Levenberg–Marquardt algorithm-based radial basis function neural network is used to compensate for the error of the torque measurement system..eparameters of the RBF neural network are settled according to the characteristics of the additional torque and the torque calibration results. .e experimental results show that the torque measurement accuracy of the torque measurement system can reach 0.1% FS after torque calibration and error compensation.